解決方案
<USG5100>sy
Enter system view,return user view with Ctrl+Z.
[USG5100]diag
Warning:Commands in the diagnose view are used for thoubleshooting.Running certain Commands in the diagnose view may cause device anomaly or service interruption.Use such commands under the instructions of HUAWEI technical engineers.
[USG5100-diagnose]display reset reason
Time Reset Reason
重啟原因
15-01-28 10:50:28 Command reboot
使用reboot命令重啟
15-01-05 11:33:54 Command reboot
使用reboot命令重啟
15-01-05 10:53:37 Command reboot
使用reboot命令重啟
14-12-16 19:46:08 Command reboot
使用reboot命令重啟
14-11-13 16:15:08 Power off
電源下電重啟
14-08-19 17:02:36 Reset key reboot
系統(tǒng)復(fù)位重啟
14-08-19 16:47:32 Power off
電源下電重啟
00-04-03 05:02:15 Power off
電源下電重啟
00-04-01 23:55:07 Power off
電源下電重啟
<Huawei>system-view
[Huawei]diagnose
[Huawei-diagnose]display reset-reason
[Huawei-diagnose]display inspect black-box record 6 0 0 0
[Huawei-diagnose]display inspect black-box record 8 0 0 0
[Huawei-diagnose]display inspect black-box record 10 0 0 0
[Huawei-diagnose]display inspect black-box record 11 0 0 0
[Huawei-diagnose]display inspect black-box record 12 0 0 0
[Huawei-diagnose]display inspect black-box record 13 0 0 0
[Huawei-diagnose]display inttrace level 1
[Huawei-diagnose]display inttrace level 2
[Huawei-diagnose]display inttrace level 3
[Huawei-diagnose]display lastwords all |